ISO Oxygen Index. ISO , Determination of burning behaviour by oxygen index. Areas of use. All types of plastics that are self-supporting and in the. l’indice d’oxygène —. Partie 2: Essai à la température ambiante. STANDARD. ISO. Second edition. Reference number. ISO (E). ISO Plastics Determination of burning behaviour by oxygen index Part 2: Ambient- temperature test. ISO Burning test for Oxygen Index test.

Author: Ketaxe Akinonris
Country: Togo
Language: English (Spanish)
Genre: Health and Food
Published (Last): 21 December 2015
Pages: 171
PDF File Size: 12.58 Mb
ePub File Size: 17.15 Mb
ISBN: 680-7-47319-433-4
Downloads: 20142
Price: Free* [*Free Regsitration Required]
Uploader: Gronos

Depending on the type of material the thickness is different.

Oxygen Index

Verify dimensions with test lab. Burning test for Oxygen Index test – Principle.

Conquered the Summit of London. The sample dimensions iso 4589-2 on the type of material. Reduced test series, one specified oxygen concentration. At least 20 samples with the uso 80 — mm x 10 mm, thickness 4 or 10 mm.

BS EN ISO 4589-2:2017

iso 4589-2 Areas of use All types of plastics that are self-supporting and in the form of vertical bars or sheet up to Results obtained in accordance with this part of ISO must not be used to describe or appraise the fire hazard presented by a particular material or shape under actual fire conditions, unless used as one element of a fire risk assessment that takes into account all of the factors pertinent to the assessment iso 4589-2 the fire hazard of a particular application for the iso 4589-2.

Dimensions in the table are of an original film from which the rolled form is made. Iso 4589-2 size for self supporting moulding or sheet materials, for electrical purposes. The results obtained are dependent upon the shape, orientation and isolation of the test specimen and the conditions of ignition.

Example of products that can be tested according to this method Plastic materials, cable insulation, duct insulation, laminates. For comparative purposes, a procedure is provided for determining whether or not the oxygen index of a material lies above some specified minimum value.

TOP Related Posts  MANYU SUKTAM EBOOK

Automatic flow control gives oxygen level adjustment by turning one single valve. Sample holders for both rigid and flexible samples supplied. The materials can be solids, laminates or cellular. Supplied Other Service requirements: The results are defined as iso 4589-2 index values.

For particular materials or applications, it may be necessary or appropriate to specify different test conditions. This makes the unit as automatic as is feasible. Results obtained from test specimens of. Exhibited at Interflam A Iso 4589-2 Scientific plc Company.

The upper end of the specimen is ignited and the subsequent burning behaviour of the specimen is observed to compare the period for which burning continues, or the length of specimen burnt, with specified limits for such burning.

Plastics isp Determination of 458-2 behaviour by oxygen index — Part 2: The upper end of iso 4589-2 specimen is ignited and the subsequent burning behaviour of the specimen is observed to compare the period for which burning continues, or the length of the specimen burnt, with specified limits for such burning. A small test specimen is supported vertically in a mixture of oxygen and nitrogen flowing upwards through a transparent chimney. Oxygen index results obtained using the methods described in this iso 4589-2 of ISO can provide a sensitive iso 4589-2 of the burning characteristics of materials under certain controlled laboratory conditions, and hence may be iso 4589-2 for quality control purposes.

By testing a series of specimens in different iso 4589-2 concentrations, the minimum oxygen concentration is estimated.

Fire Testing Technology | Oxygen Index

This is a considerable improvement over systems sio use analogue 4859-2 or require flow matching and the use of graphs or tables to calculate oxygen concentrations.

The FTT unit has been designed to be compact for efficient use in iso 4589-2 standard fume cupboard or under a simple ventilation hood that we can iso 4589-2 supply if required.

TOP Related Posts  LEGEA 230 ASOCIATII DE PROPRIETARI ACTUALIZATA 2012 PDF

By testing a series of specimens in different oxygen concentrations, the minimum oxygen concentration is estimated. If the film is very thin, it may be necessary to combine two or more films together in the preparation of iso 4589-2 rolled film so as to obtain results similar to those nominally obtained with the specimen form Vl.

Areas of use All types of plastics that are self-supporting and in the form of vertical iso 4589-2 or sheet is to The materials can be solids, laminates or cellular.

The above dimensions are for moulded or cellular materials. By testing a series of specimens in different oxygen concentrations, the minimum oxygen concentration is estimated. Its ease of use together with high levels of precision has made this technique a primary characterising and quality control tool to the plastic and electric cable industries and iso 4589-2 has iso 4589-2 specified by several military and transport groups.

Test procedure A small test specimen is supported vertically in a mixture of oxygen and nitrogen flowing upwards through a transparent chimney.

ISO Oxygen Index

This part of ISO specifies iso 4589-2 for determining the minimum concentration of iso 4589-2. The Oxygen Index sio, perhaps, the most economical and precise quality control test of combustible materials. Stabilised oxygen percentages are read from the digital readout and no additional flow adjustments are required.

A method is provided for testing flexible sheet or film materials while supported vertically.

The technique measures the minimum iso 4589-2 of oxygen in the test atmosphere that is required to marginally iso 4589-2 combustion.

The method is refered to in the standard for fire behavour of materials and components in railway applications EN